Ductwork cleaned at the source, then verified

Supply, return and extract ductwork inspected by camera, cleaned mechanically under negative pressure, and checked afterwards from the same access points.

Starts with
A camera inspection and a written finding
Method
Mechanical agitation, negative air with filtered capture
Fire dampers
Located, checked and recorded during the clean
Verification
Same access points, photographed before and after
Delivery
Self-delivered

Duct cleaning removes dust and debris from ventilation ductwork by agitating it loose and capturing it under negative pressure, then verifying the result. It should follow an inspection, not a calendar. ITF inspects by camera first, cleans run by run, and hands you before and after images taken from the same access points.

The shared facility section with the ductwork layer drawn on it: an air handling unit on the plant deck feeding a supply riser down the core, a branch duct with grilles under every slab, a fire damper where each branch leaves the core, and level 2 highlighted as the zone being cleaned under negative air with the area below protected.SECTION A-A / SAME SITE, ONE LAYER SHOWNL3L2L1B1YARD AND PERIMETEREXTERNALAHU, LOCKED OUT PER ZONEZONE 2 BELOWPROTECTED, TONIGHTNAWHAT EACH ZONE RECORDSCAMERA FINDINGPER RUNAHUOFF FOR THE ZONEZONE BELOWPROTECTEDFIRE DAMPERSLOCATED, CHECKEDAFTER IMAGESSAME POINTSZONE BY ZONE, OUT OF HOURSZONE UNDER NEGATIVE AIRCROSSED BOX: FIRE DAMPERNA: NEGATIVE AIR UNITDUST IS DRAWN TO A FILTER, NOT BLOWN INTO THE NEXT ROOM.ONE SITE, DRAWN ONCE. EVERY FM PAGE SHOWS THE SAME BUILDING WITH ONE LAYER ON IT.
The ductwork layerZone by zone, out of hoursSwipe to pan
A supply duct in section running from an air handling unit across a ceiling void to three branch grilles, with four numbered access points marked by a camera. A negative air unit at the far end draws debris along the duct. A fire damper at a wall crossing is checked. Below, the same access point is shown before and after cleaning, beside the eight stages of the clean.CEILINGAHUOFF, LOCKED OUTNEGATIVE AIRFILTEREDFIRE DAMPERCHECKED, RECORDED1234ZONE BELOW, PROTECTEDOFFICE FLOOR, OUT OF HOURSDEBRIS AGITATED LOOSE, DRAWN TO THE NEGATIVE AIR UNITACCESS POINT 3, SAME POSITIONBEFOREAFTERINSPECT, CLEAN, VERIFY01 INSPECT02 ISOLATE03 NEGATIVE AIR04 AGITATE05 COILS06 DAMPERS07 ACCESS08 VERIFY
A duct run, cleaned toward the capture pointFour access points, one fire damperSwipe to pan
  1. 01 Enquiry
  2. 02 Site survey
  3. 03 Scope and quote
  4. 04 Mobilisation
  5. 05 Planned schedule
  6. 06 Execution
  7. 07 Monthly report
  8. 08 Management review
  9. 09 Next cycle

Ductwork cleaned at the source, then verified sits at step 6 of the fm operating cycle. You receive closed work orders with photo evidence.

01

Fogging is not cleaning

Some duct sanitising is a biocide sprayed into the duct through a grille.

The dust stays where it was, now damp with chemical, and some of that chemical ends up in the air people breathe. Dust and debris have to be removed physically.

Where disinfection is genuinely needed, after water damage or mould, it follows the clean with a product suitable for that use. It does not replace the clean.

02

How the clean runs

StageWhat happens
InspectCamera at every access point; photographs and a written finding per run.
Isolate and containAir handling unit off and locked out, the section sealed, and the area below protected.
Negative airA filtered negative air unit connected, so dislodged dust is captured rather than blown into rooms.
Agitate and captureBrushes and air tools work the debris loose toward the capture point, run by run.
Coils and plenumsCoils, plenums and the unit casing cleaned, and drain pans cleared.
Fire dampersEach damper located, checked for operation and recorded.
AccessAccess panels fitted where runs cannot otherwise be reached, as a works item.
VerifyThe same access points photographed after cleaning, and the report sets them side by side.
03

Evidence from the same positions

01

The pre-clean inspection report

Camera images and a written finding for every run, including the runs found clean.

02

The post-clean verification report

The same access points photographed after cleaning, set side by side with the before images.

03

The fire damper record

Each damper located and checked, and any damper needing work referred to the fire damper specialist.

04

The access panel schedule

Where panels were fitted or are recommended, so the next inspection reaches the whole run.

05

Recommendations for the next inspection

When to look again, and what would bring that date forward.

04

An office floor after a fit-out

An office floor in Dammam reopens after a fit-out. Within a week, staff report dust on desks and irritation by the afternoon. The fit-out contractor says the ducts were covered during the works.

The camera shows fine construction dust along the supply runs and heavier deposits at the branch takeoffs nearest the new partitions. Two fire dampers are found closed. We clean the floor's supply and return over two nights, zone by zone under negative air, clean the air handling unit's coil and plenum, and record both dampers for the fire damper specialist to reset.

The landlord holds a pre-clean inspection report, a post-clean verification report with side-by-side images from the same access points, a fire damper record showing both dampers referred and reset, an access panel schedule, and a recommendation that future fit-out method statements include duct protection.

05

When to clean, and how to work around people

When ductwork actually needs cleaning

Not every year by default. The honest triggers are the ones the camera or the building gives you, and healthcare areas follow what the infection control lead requires. A run that inspects clean is reported as clean, with its photographs.

  • Visible debris at grilles or on the camera
  • Construction or renovation dust in the system
  • Water ingress or mould
  • Air quality complaints traced to the system rather than the room
  • Restarting a building after a long shutdown
06

Questions before the camera goes in

Q01

How often should ducts be cleaned?

When inspection shows they need it. Many buildings need cleaning far less often than annual contracts assume, and some need it more.

Q02

Will it disrupt our work?

Cleaning happens out of hours, zone by zone, with the area below protected. The air handling unit is off only for the zone being cleaned.

Q03

We have mould in the ducts. Is cleaning enough?

Find and fix the moisture first, or the mould returns. Then clean, and disinfect with a suitable product where the finding calls for it.

Q04

Does this cover kitchen extract?

Kitchen extract is a grease system with its own method, from the canopy to the roof fan. It is cleaned to the kitchen hood cleaning scope.

Q05

Do you reset fire dampers?

We locate and check them during the clean. Resetting and repairing dampers is fire safety work, done by the approved specialist in your fire file, and their record sits alongside ours.