ITF Hygienix · DOSE

A dilution on a chart is a hope

Dispensers and dosing units specified position by position in your zone plan and supplied per site, so the dilution comes out of the wall and not out of a guess.

Positions
Specified in the zone plan
Ratio
Set from the product label
Supply
Per site, against the plan
Charts
One per station, its own products only
Units you have
Recorded, and kept where they fit

DOSE is the Hygienix dosing line: hand dispensers, dilution stations, sink dosing and bucket fill units. Each position is specified in the zone plan, matched to the FORMULA product it dispenses and the label ratio, and supplied per site. The chart above each unit lists only the products on that unit.

A janitor-room wall in elevation. Three feeds on pickup lances run up to a wall dilution station, highlighted, with a bottle fill and a bucket fill below it. Above it, a chart listing three products, each reading label ratio, and a check card. A test strip is held against its scale at the bucket outlet. A side panel compares dosing by eye, by chart and by a fixed unit.JANITOR ROOM WALLWATER IN, DRAIN BELOWSTATION CHART, THIS UNIT ONLYPRODUCT 1LABEL RATIOPRODUCT 2LABEL RATIOPRODUCT 3LABEL RATIOCHECK CARDREADINGAT OUTLETWHENPLAN FREQUENCYWHOINITIALSDILUTION STATIONRATIO SET FROM THE LABELFEED 1LANCEFEED 2LANCEFEED 3LANCEBOTTLE FILLBUCKET FILLSTRIP AGAINST ITS SCALE, AT THE BUCKET OUTLETWHERE THE RATIO LIVESBY EYEVARIES BY PERSONBY CHARTVARIES BY READERBY UNITFIXED AT THE WALLCHECKEDSTRIP AT OUTLETRECORDEDCHECK CARDWHAT THE CHART CARRIESONLY THIS UNIT'S PRODUCTSEACH ROW PRINTED FROM A LABELNO FIGURE FROM MEMORY
The ratio lives in the wallAnd the check is taken where the product comes outSwipe to pan
  1. 01 Enquiry
  2. 02 Zone survey
  3. 03 Zone plan
  4. 04 Supply
  5. 05 At the position
  6. 06 Verify
  7. 07 Review

A dilution on a chart is a hope sits at step 4 of from survey to supply. You receive a bill of materials and a reorder quantity per position.

01

Two honest reasons this line exists

Almost every audit finding about chemical strength is really a finding about a missing dispenser.

The first reason is control. A dilution written on a chart depends on someone reading it, finding the measure and using it at the end of a long shift. A dilution coming out of a fixed unit depends on the unit, and the unit gets checked at the outlet. The strength stops being a behaviour. That is the only version that survives a new starter, a night shift and an unannounced audit.

The second reason is commercial, and we would rather write it down than pretend otherwise. A dispenser places the chemistry. It is fitted once, and the product it dispenses is bought every month. That is why suppliers in this category offer dispensers, and it is also why we specify around hardware you already own rather than insisting you replace it.

02

The positions a plan usually names

Each position gets a unit, or a deliberate decision not to fit one. The pack that feeds it is decided per position and confirmed with the quote.

PositionUnitProduct
Janitor room or chemical storeTwo- or four-product dilution station, with bottle and bucket fillDegreaser, floor cleaner, food-contact sanitiser
Pot wash and utensil sinkSink dosing unitFood-contact surface sanitiser
Remote position with no plumbingNo unit: tablets counted into a bucket marked at the fill lineSanitising tablets
Washroom basinWall-mounted soap dispenser, emptied and cleaned before each refillLiquid hand soap
Zone door, after the basinTouch-free or elbow-operated gel dispenserHand sanitiser gel
Reception deskNo fixed unitHand sanitiser gel
03

Documents at every station

01

The dosing specification per position

Unit, feed, product and ratio, with the ratio taken from the product label.

02

A chart for each station

Carrying only its own products, printed from their labels.

03

The commissioning record

A strip reading at every outlet, taken the day the unit went in.

04

A check card at every station

Date, reading and initials, filled in at the outlet on the plan's frequency.

05

Decals for every bottle the station fills

Product, dilution and hazard panel, matched to the station that fills it.

04

How a position is decided

  1. 01

    Find the water and the drain

    Pressure, a drain, and a wall that can carry the tube run. Most disappointing installs were chosen on a drawing, not on the wall.

    On the wall
  2. 02

    Follow the bucket

    Where the bucket is actually filled, and how far it is carried. A station forty metres from the work is a station people stop using.

    On the floor
  3. 03

    Decide how the product arrives

    A drum on a pickup lance, a pack carried in, or tablets. The pack follows the position, not the price list.

    Feed
  4. 04

    Print the chart for that station

    Only the products on that unit, from their labels. A chart listing everything is a chart nobody reads.

    Chart
  5. 05

    Check the outlet, not the dial

    A strip in the bucket at commissioning. The dial says what it was set to; the strip says what came out.

    Commissioning
  6. 06

    Units drift, and nobody hears it

    Metering tips wear. Water pressure changes through the day. A blocked foot valve pulls air instead of product. So every station carries a check card beside its chart: a strip at the outlet on the plan's frequency, the date, the reading and the initials. The check happens at the station, not in an office afterwards.

    Ongoing
05

A catering kitchen that doses by jug

An event catering kitchen in Khobar makes up all its chemicals by eye from 5 litre packs in the wash-up. The same jug measures degreaser in the morning and sanitiser in the afternoon.

The survey finds a plumbed wall in the janitor room with a drain beneath it, twelve metres from the wash-up. The plan puts a four-product station there for the degreaser, the floor cleaner and the food-contact sanitiser, with one position spare. The pot wash gets a sink dosing unit for the sanitiser. The kitchen door gets a touch-free gel dispenser after the basin, and the basin gets a wall soap dispenser.

At commissioning, a strip is taken at every outlet and written on the station's check card. The jug leaves the building.

The kitchen holds a dosing specification per position, a chart for each station, the commissioning record with its strip readings, a check card at every station, and decals for the bottles each station fills.

06

Dosing questions from kitchens and FM

Q01

We already have dispensers. Will you work with them?

Yes. The survey records what is fitted. Where a unit is set to a ratio the label does not want, the plan says so and gives the change. Replacing working hardware is not a recommendation we make lightly.

Q02

Why does the chart only list one station's products?

Because a chart listing everything is how the right-looking row for the wrong product gets used with complete confidence.

Q03

How do we know a station is still accurate?

Measure at the outlet with a strip, on the plan's frequency. Tips wear and pressure changes, and neither announces itself.

Q04

Do you supply a particular brand of dispenser?

The plan specifies what each position needs: the product, the ratio, bottle or bucket fill, and touch-free or not. The unit is agreed per site.

Q05

Is the signage generic?

No. Every chart, decal and check card is printed from your plan and your product labels.

Take the guess out of the bucket

Tell us where your crew makes up solutions today. The survey finds the positions, and the plan specifies the unit, the product and the chart for each one.

Ask about dosing for your site