Cold rooms that hold temperature and prove it

Cold rooms, freezers, reach-ins and display cases maintained against the temperature record your auditor will ask for.

Scope
Cold rooms, freezers, reach-ins, display cases, alarms
Every visit
Temperature record reviewed, excursions actioned
Doors and seals
Registered and inspected per door
Survey to schedule
Within two weeks
Plant overhaul and racks
Managed specialist

Refrigeration maintenance keeps cold rooms, freezers and display cases at temperature: condensers, evaporators, defrost, door seals, controls and alarms, with the temperature record checked every visit. Plant overhauls, rack systems and warranty work are managed specialist work, done by refrigeration specialists we supervise.

The shared facility section with the refrigeration layer drawn on it: a cold room and a freezer on the ground floor, condensing units in the yard with refrigerant lines into the building, and the alarm path from the cold room up to the on-call supervisor, with four numbered check points.SECTION A-A / SAME SITE, ONE LAYER SHOWNL3L2L1B1YARD AND PERIMETEREXTERNALFREEZER FZ-01SEAL, FRAME HEATERCOLD ROOM CR-01LOGGER ON THE WALLCONDENSING UNITSIN THE YARDON-CALL SUPERVISORALARM TESTED QUARTERLY1234READ AT EVERY VISITLOGGER DATAREVIEWEDEXCURSIONSCAUSE AND ACTIONPROBESOFFSET RECORDEDDOOR SEALSPER DOORDEFROSTPROVEDALARMREACHES A PERSONTHE RECORD IS WHAT IS AUDITEDREFRIGERANT LINESALARM PATH01-04 CHECK POINTSAN ALARM THAT REACHES NOBODY IS WORSE THAN NO ALARM, BECAUSE EVERYONE ASSUMES IT WORKS.ONE SITE, DRAWN ONCE. EVERY FM PAGE SHOWS THE SAME BUILDING WITH ONE LAYER ON IT.
The refrigeration layerRooms inside, condensers outsideSwipe to pan
A cold room drawn in section: the condenser outside on a sunlit wall, the evaporator inside near the ceiling, the door with its seal highlighted, a temperature logger on the wall and an alarm line running out to the on-call supervisor, with four numbered check points and the excursion log.WEST WALL, AFTERNOON SUNCOLD ROOM CR-01CONDENSERON THE SUNLIT WALLREFRIGERANT LINEEVAPORATORCOIL, FANS, DRAINDOOR AND SEALLOGGERON-CALL SUPERVISORA PERSON, NOT A ROOM1234EXCURSION LOGEVENTEVERY ONECAUSEWRITTENACTIONWRITTENPROBE OFFSETRECORDEDFOUR CHECK POINTS, EVERY VISIT01 CONDENSER COIL AND SITING02 EVAPORATOR ICE AND DRAIN03 DOOR SEAL, CLOSER, HEATER04 ALARM PROVED TO A PERSON
Cold room, four check pointsCondenser, evaporator, door seal, alarm pathSwipe to pan
  1. 01 Enquiry
  2. 02 Site survey
  3. 03 Scope and quote
  4. 04 Mobilisation
  5. 05 Planned schedule
  6. 06 Execution
  7. 07 Monthly report
  8. 08 Management review
  9. 09 Next cycle

Cold rooms that hold temperature and prove it sits at step 6 of the fm operating cycle. You receive closed work orders with photo evidence.

01

Stock loss is the real cost

The maintenance bill for a cold room is small. The stock inside it is not, and neither is the audit finding when the temperature record has a gap.

Most failures are ordinary. A condenser on a sun-facing wall, clogged with dust. A torn door seal letting warm, humid air in, which ices the evaporator. A defrost heater that stopped working in winter and was only noticed in May. An alarm that sounds in an empty building at 03:00 and reaches nobody.

More of it starts at the door than in the plant. Seals split, closers weaken, strip curtains get tied back because they slow the forklifts, and freezer door frames ice up when their heaters fail. It is dull, and it is where most of the ice comes from.

02

Condensers to alarms, the full list

ComponentWhat is doneTypical interval
CondensersCoils cleaned, fans and mounts checked, airflow and siting noted.Monthly in summer, quarterly otherwise
EvaporatorsIce build-up, drain line, fans and coil condition.Monthly
DefrostHeaters and timers proved, and the drain heater on freezer drains checked.Quarterly
Doors, seals and heatersSeal condition, closers, strip curtains and the frame heaters on freezer doors, each door on its own line of the register.Monthly
Controls and probesSetpoint against reading, and each probe checked against a reference thermometer with the offset recorded.Monthly
AlarmsThe high temperature alarm triggered and proved to reach a person.Quarterly
Refrigerant circuitPressures recorded, and leaks found and repaired rather than topped up.Every service
Compressors, circuit rebuilds and racksCompressor replacement, refrigerant circuit rebuilds, supermarket rack systems and warranty work, done by refrigeration specialists. We diagnose, write the case with readings, supervise the visit and keep their report beside ours. Managed specialist work.As diagnosed
03

What sits in the cold room file

01

The unit service sheet

One per cold room per visit: readings, defrost, seals, condenser condition and the technician's name.

02

The excursion log

Every excursion since mobilisation with its cause and the action taken, which is the page a customer or regulator audit asks for.

03

The alarm test record

Each quarterly test: the alarm triggered, who it reached and when.

04

The door and seal register

Every door with its seal, closer, strip curtain and frame heater condition.

05

The probe check records

Each probe against a reference thermometer, with the offset, every month.

06

The defect list

Anything beyond the service, such as a condenser in full afternoon sun, with a recommendation and a priority.

04

The temperature record, every visit

An auditor does not ask whether the cold room works. They ask for the record: continuous, readable, and with an action written against every excursion.

  1. 01

    Read the logger

    The data since the last visit reviewed, gaps included, before anything is touched.

    First
  2. 02

    Write the action

    Every excursion gets a cause and an action written against it, so the log answers the auditor's next question.

    Per excursion
  3. 03

    Check the probes

    Each probe compared with a reference thermometer and the offset recorded, which catches a drifting probe.

    Monthly
  4. 04

    Prove the alarm path

    The alarm triggered and followed to the person it is meant to reach, with the test logged.

    Quarterly
05

An audit finding and a phone switched off

A food distributor in Dammam's Second Industrial City runs three cold rooms and a freezer. Its last customer audit found excursions on the logger with no recorded action, and the night alarm had been ringing a phone that was switched off.

Our survey finds a condenser on the west wall in full afternoon sun and matted with dust, a torn seal on the freezer door, and an iced evaporator. The condenser is cleaned and a shade structure recommended. The seal is replaced and defrost is proved. The alarm is re-routed to the on-call supervisor's phone and tested with the warehouse manager watching.

The client holds an excursion log with a cause and an action against every event since mobilisation, an alarm test record, a door and seal register, probe offset records and a defect list with the shade recommendation priced.

06

Asked by warehouse and food-site managers

Q01

Can you calibrate our temperature probes?

We check them against a reference thermometer and record the offset, which catches a drifting probe. A traceable calibration certificate comes from an accredited calibration provider, which we can arrange and keep on your file.

Q02

Who answers the alarm at night?

Whoever the contract names. We set up the call path, test it quarterly and log each test. An alarm that reaches nobody is worse than no alarm, because everyone assumes it works.

Q03

Do you maintain supermarket display cases?

Plug-in cases, and remote cases on the case side, yes. Central rack plant is managed specialist work, done by a refrigeration specialist we supervise.

Q04

Is this relevant to SFDA?

For food storage, temperature records are part of what SFDA and customer auditors look at. We keep them in the form they ask for; how the whole system is judged is theirs to decide.

Q05

Can you respond when a cold room fails?

Yes. Cold room failures are written as P1 or P2 in your priority schedule, with the response window set for your site in the contract.

Book a site survey

Bring the last three months of logger data to the survey. The excursions with no action written against them are where the scope starts.